All About Iontophoresis

With respect to the suffering and the condition of a patient, device selection often plays a decisive function in the possible therapeutic achievement. With appropriate equipment selection you employ a high probability of achievement with an iontophoresis gadget to dry. Not necessarily with treatment strictly regarding to manual a success (freedom from sweat) can be reached. In this instance, we are of training course and especially following the purchase of training course – with our experience since 1999 in the field of iontophoresis – aside. With the method Iontophoresis, many manage to “get dry”.

really great feeling when hands / ft / armpits are dried out and warm instead of wet and cool (frog hands). Still, many users delivered their iontophoresis machine back again – why? We also asked ourselves this issue, above all because we are also thinking about providing our clients with ideal and successful therapy.

Background info: There are two types of treatment streams: Pulse and DC. DC devices deliver the effect of greater efficiency (sweat level of resistance) with the same current setting. Today you could come to the final outcome: Fine, I’m sweating intensely, so DC is better for me, and cheaper it is! Unfortunately this is not always correct: the treatment with pulse current gadgets is simply more pleasant with the same current environment. As a result, with a pulse-current gadget, you can often drive higher currents when compared to direct current, because the current is way better tolerated.

Nevertheless, the limit values ​​must not be exceeded (Dr. Hoenle specifies a maximum of 25 mA for your feet, 15 mA for the hands and 5 mA for the treatment of the underarms as a limit). These values ​​are not normally attained with immediate current gadgets, unless the patient is completely insensitive to the procedure stream, which is quite rare, nevertheless, and your skin must also join the whole. Even on your feet, 30 mA DC is a term! If you can set 5 mA with a pulse power unit beneath the armpits, this could be enough to record successful since the skin there is quite thin (and unfortunately sensitive) and for that reason doesn’t need higher currents. Specifically with the armpits, DC devices can sometimes tolerate just 1mA and therefore in some instances no therapeutic achievement may be accomplished. The same pertains to the hands, where you frequently have minor injuries (nail bed, etc.) where not only direct currents can be very painful. It isn’t so much the topic of the feet, but also the rule of the term: The pulse current is normally often a lot more pleasant there as well.

Leave a Reply